Special-Sensors for Automation Flow Sensors EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com1.02 E10220 Technique and application for flow sensors Technique and application for flow sensors, amplifiers and compact models . . . . . . . . . . . . 1.03 - 1.07 Terminology / Setting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.08 - 1.09 Technique and application for flow sensors inline-digital display . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.10 Ex area certification . . . . . . . . . . . . . . . . . .…
File type: application/pdf
Referenced at:
VACUUM SOLUTIONS VACUUM SOLUTIONS c a t á l o g o 3 Lo s d ibu jos en 3D es tá n d isp on ibl es en el si tio w eb vu ot ot ec nic a.n et TABLAS DE CONVERSIÓN DE LAS UNIDADES DE MEDIDA DEL VACÍO Y DE LA PRESIÓN PÁG. 3.00 VACUÓMETROS Y MANÓMETROS PÁG. 3.01 ÷ 3.04 VACUÓMETRO CON PUNZÓN DE ACERO PÁG. 3.05 VACUÓSTATOS MINI NEUMÁTICOS PÁG. 3.06 VACUÓSTATO MINI ELECTROMECÁNICO PÁG. 3.07 MICROVACUÓSTATOS DIGITALES PÁG. 3.08 ÷ 3.09 VACUÓSTATO ANALÓGICO PÁG. 3.10 ÷ 3.11 VACUÓSTATOS Y PRESOSTATOS DIGITALES PÁG. 3.12 ÷ 3.13 VACUÓSTATOS DIGITALES PÁG. 3.14 ÷ 3.15 VACUÓSTATOS Y PRESOSTATOS DIGITALES PÁG.…
File type: application/pdf
Referenced at:
58 Read the precautions on pages 7 to 12 in the introduction before use. Eliminating causes of particle formation with PFA-molded body Orifice: Ø8/Ø10/Ø12/Ø16/Ø20/Ø22/Ø25 AMD2123 / AMD3 1 2 3 / AMD4 1 2 3 / AMD5 1 2 3 Series Air-operated valve for chemical liquids Subject to Export Trade Control Ordinances *Target: Valves with Ø12 or larger orifice Specifications Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Port size (Note 1) Orifice Cv…
File type: application/pdf
Referenced at:
58 Read the precautions on pages 7 to 12 in the introduction before use. Eliminating causes of particle formation with PFA-molded body Orifice: Ø8/Ø10/Ø12/Ø16/Ø20/Ø22/Ø25 AMD2123 / AMD3 1 2 3 / AMD4 1 2 3 / AMD5 1 2 3 Series Air-operated valve for chemical liquids Subject to Export Trade Control Ordinances *Target: Valves with Ø12 or larger orifice Specifications Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Port size (Note 1) Orifice Cv…
File type: application/pdf
Referenced at:
58 Read the precautions on pages 7 to 12 in the introduction before use. Eliminating causes of particle formation with PFA-molded body Orifice: Ø8/Ø10/Ø12/Ø16/Ø20/Ø22/Ø25 AMD2123 / AMD3 1 2 3 / AMD4 1 2 3 / AMD5 1 2 3 Series Air-operated valve for chemical liquids Subject to Export Trade Control Ordinances *Target: Valves with Ø12 or larger orifice Specifications Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Port size (Note 1) Orifice Cv…
File type: application/pdf
Referenced at:
16 Read the precautions on pages 7 to 12 in the introduction before use. Orifice: Ø8/Ø10 AMD31232 Series Stainless steel body air-operated valve for chemical liquids Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Operation section Chemical liquids, pure water (Note 1) 5 to 120 0.9 0 to 0.3 (Note 2) 0 to 0.1 (Note 2) 0 (at, water pressure) 0 to 0.1 (Note 2) 0 to 60 30…
File type: application/pdf
Referenced at:
16 Read the precautions on pages 7 to 12 in the introduction before use. Orifice: Ø8/Ø10 AMD31232 Series Stainless steel body air-operated valve for chemical liquids Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Operation section Chemical liquids, pure water (Note 1) 5 to 120 0.9 0 to 0.3 (Note 2) 0 to 0.1 (Note 2) 0 (at, water pressure) 0 to 0.1 (Note 2) 0 to 60 30…
File type: application/pdf
Referenced at:
16 Read the precautions on pages 7 to 12 in the introduction before use. Orifice: Ø8/Ø10 AMD31232 Series Stainless steel body air-operated valve for chemical liquids Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Operation section Chemical liquids, pure water (Note 1) 5 to 120 0.9 0 to 0.3 (Note 2) 0 to 0.1 (Note 2) 0 (at, water pressure) 0 to 0.1 (Note 2) 0 to 60 30…
File type: application/pdf
Referenced at:
84 Read the precautions on pages 7 to 12 in the introduction before use. MMD34502 Series Stainless steel body chemical liquid manual valve Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Installation attitude Connection Orifice Chemical liquids, pure water (Note 1) 5 to 90 1.2 0 to 0.4 0 to 0.4 0 (at, water pressure) 0 to 0.4 0 to 60 Free Ø16 Rc1/4·Rc3/8 Ø3/8" SUS weld tube Ø3/8" double barbed fitting (Note 2) Ø1/2" SUS weld…
File type: application/pdf
Referenced at:
84 Read the precautions on pages 7 to 12 in the introduction before use. MMD34502 Series Stainless steel body chemical liquid manual valve Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Installation attitude Connection Orifice Chemical liquids, pure water (Note 1) 5 to 90 1.2 0 to 0.4 0 to 0.4 0 (at, water pressure) 0 to 0.4 0 to 60 Free Ø16 Rc1/4·Rc3/8 Ø3/8" SUS weld tube Ø3/8" double barbed fitting (Note 2) Ø1/2" SUS weld…
File type: application/pdf
Referenced at: