28 Read the precautions on pages 7 to 12 in the introduction before use. Subject to Export Trade Control Ordinances Air-operated valve for chemical liquids Orifice: Ø20 AMD51232 Series Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Orifice Bypass orifice (when bypass is installed) Cv value Operation section Chemical liquids, pure water (Note 1) 5 to 90 (Note 2) 0.9 0 to 0.3 (Note 4) 0 to 0.1…
File type: application/pdf
Referenced at:
28 Read the precautions on pages 7 to 12 in the introduction before use. Subject to Export Trade Control Ordinances Air-operated valve for chemical liquids Orifice: Ø20 AMD51232 Series Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Orifice Bypass orifice (when bypass is installed) Cv value Operation section Chemical liquids, pure water (Note 1) 5 to 90 (Note 2) 0.9 0 to 0.3 (Note 4) 0 to 0.1…
File type: application/pdf
Referenced at:
New Products CC-776A Quick exhaust valve QEV2 Series New Product Outstanding exhaust characteristics are achieved with the large flow rate design. Port size variation Port sizes; Rc1/8 to Rc1 are available. Various options • Fluoro rubber specifications joined in option • Mounting bracket is available (small bore size type) Ecological products • Lead and hexavalent chrome-free ecological design • Painting free • Easy sorting materials Features Refer to the "safety precautions" on the back before operating. Working fluid Max. working pressure Min. working pressure Withstanding pressure Fluid…
File type: application/pdf
Referenced at:
28 Read the precautions on pages 7 to 12 in the introduction before use. Subject to Export Trade Control Ordinances Air-operated valve for chemical liquids Orifice: Ø20 AMD51232 Series Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Orifice Bypass orifice (when bypass is installed) Cv value Operation section Chemical liquids, pure water (Note 1) 5 to 90 (Note 2) 0.9 0 to 0.3 (Note 4) 0 to 0.1…
File type: application/pdf
Referenced at:
260 Reduced wiring block manifold Body porting MN4GA1/2-T* Series • Applicable cylinder bore size: 20 to 80mm Manifold common specifications Descriptions Manifold type Installation method Air supply/exhaust air method Pilot exhaust method Piping direction Other specifications are as same as MN4GA (Page 248). Block manifold DIN rail mount type Common supply/exhaust (check valve incorporated) Main/pilot valves' common exhaust (pilot exhaust check valve incorporated) Valve top direction Electrical specifications Descriptions Rated voltage Fluctuation range Holding current A Power con- sumption W…
File type: application/pdf
Referenced at:
188 Reduced wiring manifold (common gland/D-sub connector/flat cable connector) Body porting direct mount type M4GA1/2/3-T* Series DIN rail mount type M4GA1/2/3-T*D Series • Applicable cylinder bore size: 20 to 100mm Descriptions Manifold type Installation method Air supply/exhaust air method Pilot exhaust method Piping direction Other specifications are as same as M4GA (Page 156). Reduced wiring integrated type base Direct mount type/DIN rail mount type Common supply/exhaust (check valve incorporated) Main/pilot valves common exhaust (pilot exhaust check valve incorporated) Main valve/pilot…
File type: application/pdf
Referenced at:
206 Reduced wiring manifold (common gland/D-sub connector/flat cable connector) Sub base porting direct mount type M4GB1/2/3-T* Series DIN rail mount type M4GB1/2/3-T*D Series • Applicable cylinder bore size: 20 to 100 mm Wiring specifications Descriptions Left: T * When (e.g.) T50 * Right: T * R T10 * Common gland type T11* Common gland type T30* D-sub connector T50 * Flat cable 20 pins type T51* Flat cable 20 pins type T52 * Flat cable 10 pins type T53 * Flat cable 26 pins type Connection connector and Gland specifications Max. solenoid number Manifold internal wiring Wiring block position…
File type: application/pdf
Referenced at:
t a u English Speed stability High response High efficiency Hollow structure Quietness Maintainability High precision Simple structure Creating a New Way of Motion Direct Drive Motors ND-s Series ND-s HS Series HD-s Series DD-s Series Standard type suitable for various applications High-speed rotation type pursuing high-speed operation High-response type pursuing high-speed operation High-rigidity, high-precision type pursuing high rigidity and high precision P.15 P.26 P.39 P.29 P.5 P.6 P.8 P.7 Details Details Details Details Features Features Features Features Direct drive motor Direct drive…
File type: application/pdf
Referenced at:
100 Discrete direct acting 2 port solenoid valve for hot water (special purpose valve) FHB Series NC (normally closed) type Port size: Rc1/8 to Rc1/2 0.035 0.15 0.31 0.54 0.75 0.54 0.80 1.10 1.88 0.54 0.80 1.10 1.88 1.5 0.7 0.7 0.4 0.25 0.8 0.5 0.2 0.1 1.1 0.7 0.3 0.12 Individual specifications FHB 21- 6 - Z - 2 FHB 31- - 3 - 5 - 6 FHB 41- - 5 - 6 - 7 FHB 41- - 8 FHB 51- - 5 - 6 - 7 FHB 51- - 8 Port size Orifice (mm) AC 50Hz 5.5 10 16 23 Voltage Model no. FHB2 FHB3/4/5 3mA or less 6mA or less 1.5mA or less 3mA or less 100 VAC 200 VAC Le ak ag e cu rre nt 1.5 0.3 1.5 0.3 4 9 8Rc1/8 Rc1/8 Rc3/8…
File type: application/pdf
Referenced at:
100 Discrete direct acting 2 port solenoid valve for hot water (special purpose valve) FHB Series NC (normally closed) type Port size: Rc1/8 to Rc1/2 0.035 0.15 0.31 0.54 0.75 0.54 0.80 1.10 1.88 0.54 0.80 1.10 1.88 1.5 0.7 0.7 0.4 0.25 0.8 0.5 0.2 0.1 1.1 0.7 0.3 0.12 Individual specifications FHB 21- 6 - Z - 2 FHB 31- - 3 - 5 - 6 FHB 41- - 5 - 6 - 7 FHB 41- - 8 FHB 51- - 5 - 6 - 7 FHB 51- - 8 Port size Orifice (mm) AC 50Hz 5.5 10 16 23 Voltage Model no. FHB2 FHB3/4/5 3mA or less 6mA or less 1.5mA or less 3mA or less 100 VAC 200 VAC Le ak ag e cu rre nt 1.5 0.3 1.5 0.3 4 9 8Rc1/8 Rc1/8 Rc3/8…
File type: application/pdf