PUR 80A PUR 90A Rubber 80A TUBUS Operating Instructions Profile Dampers Is su e 1 .2 0 0 4 Prior to mounting, check whether the damper can be used for your specific application. The following conditions must be fulfilled: Correct dimensioning of the damper The energy absorption per stroke under the permanent load W3 must not be exceeded. Exceptions with indivi- dual impacts: In this case the W3-ratings can be exceeded by up to 40%. Please, remember that the moved load does not dece- lerate to an exact datum position and that the impact energy is not 100% absorbed. For this reason, a limited…
File type: application/pdf
Referenced at:
PUR 80A PUR 90A Rubber 80A TUBUS Operating Instructions Profile Dampers Is su e 1 .2 0 0 4 Prior to mounting, check whether the damper can be used for your specific application. The following conditions must be fulfilled: Correct dimensioning of the damper The energy absorption per stroke under the permanent load W3 must not be exceeded. Exceptions with indivi- dual impacts: In this case the W3-ratings can be exceeded by up to 40%. Please, remember that the moved load does not dece- lerate to an exact datum position and that the impact energy is not 100% absorbed. For this reason, a limited…
File type: application/pdf
Referenced at:
24 Read the precautions on pages 7 to 12 in the introduction before use. Orifice: Ø16 AMD41232 Series Stainless steel body air-operated valve for chemical liquids Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range (A — > B) Working pressure range (B — > A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Operation section Chemical liquids, pure water (Note 1) 5 to 120 0.9 0 to 0.3 (Note 2) 0 to 0.1 (Note 2) 0 (at, water pressure) 0 to 0.1 (Note 2) 0 to 60 20…
File type: application/pdf
Referenced at:
24 Read the precautions on pages 7 to 12 in the introduction before use. Orifice: Ø16 AMD41232 Series Stainless steel body air-operated valve for chemical liquids Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range (A — > B) Working pressure range (B — > A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Operation section Chemical liquids, pure water (Note 1) 5 to 120 0.9 0 to 0.3 (Note 2) 0 to 0.1 (Note 2) 0 (at, water pressure) 0 to 0.1 (Note 2) 0 to 60 20…
File type: application/pdf
Referenced at:
24 Read the precautions on pages 7 to 12 in the introduction before use. Orifice: Ø16 AMD41232 Series Stainless steel body air-operated valve for chemical liquids Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range (A — > B) Working pressure range (B — > A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Operation section Chemical liquids, pure water (Note 1) 5 to 120 0.9 0 to 0.3 (Note 2) 0 to 0.1 (Note 2) 0 (at, water pressure) 0 to 0.1 (Note 2) 0 to 60 20…
File type: application/pdf
Referenced at:
90 Read the precautions on pages 7 to 12 in the introduction before use. GMMD34502 Series Chemical liquid manual valve (manifold/branch valve) Subject to Export Trade Control Ordinances *Target: GMMD402 and 502 only Specifications Working fluid Fluid temperature Withstanding pressure Working pressure range Valve seat leakage Back pressure Ambient temperature Installation attitude Orifice Chemical liquids, pure water (Note 1) 5 to 90 (Note 3) 1.2 0 to 0.4 0 (at, water pressure) 0 to 0.4 0 to 60 Free Ø14.7 to Ø16 (Note 2) ODØ10 tube connection (fitting integrated type) ODØ12 tube connection…
File type: application/pdf
Referenced at:
90 Read the precautions on pages 7 to 12 in the introduction before use. GMMD34502 Series Chemical liquid manual valve (manifold/branch valve) Subject to Export Trade Control Ordinances *Target: GMMD402 and 502 only Specifications Working fluid Fluid temperature Withstanding pressure Working pressure range Valve seat leakage Back pressure Ambient temperature Installation attitude Orifice Chemical liquids, pure water (Note 1) 5 to 90 (Note 3) 1.2 0 to 0.4 0 (at, water pressure) 0 to 0.4 0 to 60 Free Ø14.7 to Ø16 (Note 2) ODØ10 tube connection (fitting integrated type) ODØ12 tube connection…
File type: application/pdf
Referenced at:
90 Read the precautions on pages 7 to 12 in the introduction before use. GMMD34502 Series Chemical liquid manual valve (manifold/branch valve) Subject to Export Trade Control Ordinances *Target: GMMD402 and 502 only Specifications Working fluid Fluid temperature Withstanding pressure Working pressure range Valve seat leakage Back pressure Ambient temperature Installation attitude Orifice Chemical liquids, pure water (Note 1) 5 to 90 (Note 3) 1.2 0 to 0.4 0 (at, water pressure) 0 to 0.4 0 to 60 Free Ø14.7 to Ø16 (Note 2) ODØ10 tube connection (fitting integrated type) ODØ12 tube connection…
File type: application/pdf
Referenced at:
20 Read the precautions on pages 7 to 12 in the introduction before use. Subject to Export Trade Control Ordinances Air-operated valve for chemical liquids Orifice: Ø14.7 to Ø16 AMD41232 Series Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Cv value Bypass orifice (when bypass is installed) Operation section Chemical liquids, pure water (Note 1) 5 to 90 (5 to 160) (Note 5)…
File type: application/pdf
Referenced at:
20 Read the precautions on pages 7 to 12 in the introduction before use. Subject to Export Trade Control Ordinances Air-operated valve for chemical liquids Orifice: Ø14.7 to Ø16 AMD41232 Series Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Cv value Bypass orifice (when bypass is installed) Operation section Chemical liquids, pure water (Note 1) 5 to 90 (5 to 160) (Note 5)…