Discrete direct acting 2 port solenoid valve for compressed air, manifold (special purpose valve) FAB Series NC (normally closed) type, NO (normally open) type Port size: M5, Rc1/8 to Rc1/2 26 Refer to Ending 17 for more details. Common specifications Descriptions Compressed air 0 to 1.4 (Refer to the maximum working pressure differential on the individual specifications) 2.1 (1.5 for FAB11/21) AC: -10 to 60, DC: -10 to 40 (no freezing) AC: -20 to 60, DC: -20 to 40 B No corrosive gas and flammable Direct acting poppet structure 0.2 or less Free IP65 or equivalent (Note 1) 1 1.5 1.5 2 2 3 5 3 4…
File type: application/pdf
Referenced at:
Discrete direct acting 2 port solenoid valve for compressed air, manifold (special purpose valve) FAB Series NC (normally closed) type, NO (normally open) type Port size: M5, Rc1/8 to Rc1/2 26 Refer to Ending 17 for more details. Common specifications Descriptions Compressed air 0 to 1.4 (Refer to the maximum working pressure differential on the individual specifications) 2.1 (1.5 for FAB11/21) AC: -10 to 60, DC: -10 to 40 (no freezing) AC: -20 to 60, DC: -20 to 40 B No corrosive gas and flammable Direct acting poppet structure 0.2 or less Free IP65 or equivalent (Note 1) 1 1.5 1.5 2 2 3 5 3 4…
File type: application/pdf
Referenced at:
534 Buffering functionBuffering function High precision non-rotating mechanism Space saving design Direct 2 surfaces mountDirect 2 surfaces mount A variety of sucking pad availableA variety of sucking pad available Miniature switch installation possibleMiniature switch installation possible MV C S eri es +- CK D C orp ora tio n MV C S eri es CK D C orp ora tio n Leading to compact and space saving. 6, 10 mm bore ultra compact size. Optimum for sucking and transfer process of precise parts! Overall length of axial cylinder is reduced. New compact, space saving small vacuum suction cylinders,…
File type: application/pdf
Referenced at:
68 Discrete direct acting 2 port solenoid valve for medium vacuum (special purpose valve) FVB Series NC (normally closed) type Port size: Rc1/8, Rc1/4, Rc3/8 Common specifications Descriptions 1 2 3 4 4 5 4 5 7 0.14 0.55 1.2 2.2 2.2 3.2 2.2 3.2 5.2 0.49 0.56 0.57 0.50 0.50 0.50 0.50 0.50 0.38 1.3 x 10-2 to 1 x 106 1.3 x 10-2 to 0.3 x 106 1.3 x 10-2 to 0.4 x 106 1.3 x 10-2 to 0.15 x 106 1.3 x 10-2 to 0.3 x 106 1.3 x 10-2 to 0.12 x 106 1.3 x 10-2 to 0.5 x 106 1.3 x 10-2 to 0.3 x 106 1.3 x 10-2 to 0.15 x 106 FVB MPa Pa m3/sHe Individual specifications FVB21- 6 FVB31- FVB41- FVB51- Port size…
File type: application/pdf
Referenced at:
68 Discrete direct acting 2 port solenoid valve for medium vacuum (special purpose valve) FVB Series NC (normally closed) type Port size: Rc1/8, Rc1/4, Rc3/8 Common specifications Descriptions 1 2 3 4 4 5 4 5 7 0.14 0.55 1.2 2.2 2.2 3.2 2.2 3.2 5.2 0.49 0.56 0.57 0.50 0.50 0.50 0.50 0.50 0.38 1.3 x 10-2 to 1 x 106 1.3 x 10-2 to 0.3 x 106 1.3 x 10-2 to 0.4 x 106 1.3 x 10-2 to 0.15 x 106 1.3 x 10-2 to 0.3 x 106 1.3 x 10-2 to 0.12 x 106 1.3 x 10-2 to 0.5 x 106 1.3 x 10-2 to 0.3 x 106 1.3 x 10-2 to 0.15 x 106 FVB MPa Pa m3/sHe Individual specifications FVB21- 6 FVB31- FVB41- FVB51- Port size…
File type: application/pdf
Referenced at:
534 Buffering functionBuffering function High precision non-rotating mechanism Space saving design Direct 2 surfaces mountDirect 2 surfaces mount A variety of sucking pad availableA variety of sucking pad available Miniature switch installation possibleMiniature switch installation possible MV C S eri es +- CK D C orp ora tio n MV C S eri es CK D C orp ora tio n Leading to compact and space saving. 6, 10 mm bore ultra compact size. Optimum for sucking and transfer process of precise parts! Overall length of axial cylinder is reduced. New compact, space saving small vacuum suction cylinders,…
File type: application/pdf
Referenced at:
534 Buffering functionBuffering function High precision non-rotating mechanism Space saving design Direct 2 surfaces mountDirect 2 surfaces mount A variety of sucking pad availableA variety of sucking pad available Miniature switch installation possibleMiniature switch installation possible MV C S eri es +- CK D C orp ora tio n MV C S eri es CK D C orp ora tio n Leading to compact and space saving. 6, 10 mm bore ultra compact size. Optimum for sucking and transfer process of precise parts! Overall length of axial cylinder is reduced. New compact, space saving small vacuum suction cylinders,…
File type: application/pdf
Referenced at:
58 Read the precautions on pages 7 to 12 in the introduction before use. Eliminating causes of particle formation with PFA-molded body Orifice: Ø8/Ø10/Ø12/Ø16/Ø20/Ø22/Ø25 AMD2123 / AMD3 1 2 3 / AMD4 1 2 3 / AMD5 1 2 3 Series Air-operated valve for chemical liquids Subject to Export Trade Control Ordinances *Target: Valves with Ø12 or larger orifice Specifications Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Port size (Note 1) Orifice Cv…
File type: application/pdf
Referenced at:
32 Read the precautions on pages 7 to 12 in the introduction before use. Orifice: Ø20 AMD51232 Series Stainless steel body air-operated valve for chemical liquids Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Orifice Operation section Chemical liquids, pure water (Note 1) 5 to 120 0.9 0 to 0.3 (Note 2) 0 to 0.1 (Note 2) 0 (at, water pressure) 0 to 0.1 (Note 2) 0 to 60 20 times/min or less…
File type: application/pdf
Referenced at:
58 Read the precautions on pages 7 to 12 in the introduction before use. Eliminating causes of particle formation with PFA-molded body Orifice: Ø8/Ø10/Ø12/Ø16/Ø20/Ø22/Ø25 AMD2123 / AMD3 1 2 3 / AMD4 1 2 3 / AMD5 1 2 3 Series Air-operated valve for chemical liquids Subject to Export Trade Control Ordinances *Target: Valves with Ø12 or larger orifice Specifications Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Port size (Note 1) Orifice Cv…
File type: application/pdf
Referenced at: