MEASURING AND CONTROLLING DEVICES M E A S U R IN G A N D C O N T R O L IN G D E V IC E S Jacob elektronische Mess- und Regelgeräte GmbH Verwaltung und Produktion: Düsseldorfer Straße 16 71332 Waiblingen Telefon 0 71 51 / 5 68 06-60 Telefax 0 71 51 / 5 68 06-79 E-Mail jacob@jacob-gmbh.de http://www.jacob-gmbh.de 000_Umschlag.qxp 19.03.2008 15:24 Seite 1 Jacob elektronische Mess- und Regelgeräte GmbH, Düsseldorfer Straße 16, D-71332 Waiblingen Tel.: 0 71 51/5 68 06 60 Fax: 0 71 51/5 68 06 79 3 General and functional description 5 Float switches 15 Indicators and Controls 93 Pressure Sensors…
File type: application/pdf
Referenced at:
a i r m o v i n g Pressione / pressure (mbar rel.) 1100 1050 1000 950 900 850 800 750 700 650 600 550 500 450 400 350 0 50 100 150 200 250 300 350 400 425 Po rt at a as pi ra ta / s uc tio n ca pa ci ty V (m 3 / h) − − 60Hz — 50Hz Depressione / inlet vacuum (mbar rel.) 1100 1050 1000 950 900 850 800 750 700 650 600 550 500 450 400 350 0 50 100 150 200 250 300 325 Po rt at a as pi ra ta / s uc tio n ca pa ci ty V (m 3 / h) − − 60Hz — 50Hz COMPRESSIONE / COMPRESSIONASPIRAZIONE / EXHAUST 2 2 4 4 3 3 1 1 COMPRESSORI - ASPIRATORI A CANALE LATERALE SIDE CHANNEL COMPRESSORS AND VACUUM PUMPS I valori…
File type: application/pdf
Referenced at:
a i r m o v i n g Pressione / pressure (mbar rel.) 1100 1050 1000 950 900 850 800 750 700 650 600 550 500 450 400 350 0 50 100 150 200 250 300 350 400 425 Po rt at a as pi ra ta / s uc tio n ca pa ci ty V (m 3 / h) − − 60Hz — 50Hz Depressione / inlet vacuum (mbar rel.) 1100 1050 1000 950 900 850 800 750 700 650 600 550 500 450 400 350 0 50 100 150 200 250 300 325 Po rt at a as pi ra ta / s uc tio n ca pa ci ty V (m 3 / h) − − 60Hz — 50Hz COMPRESSIONE / COMPRESSIONASPIRAZIONE / EXHAUST 2 2 4 4 3 3 1 1 COMPRESSORI - ASPIRATORI A CANALE LATERALE SIDE CHANNEL COMPRESSORS AND VACUUM PUMPS I valori…
File type: application/pdf
Referenced at:
78 Discrete direct acting 2 port solenoid valve for water (special purpose valve) NC (normally closed) type, NO (normally open) type Port size: Rc1/8 to Rc1/2 FWB Series Common specifications Descriptions 1 2 3 4 5 4 5 7 10 4 5 7 10 3 4 5 4 5 7 4 5 7 0.036 0.15 0.31 0.5 0.65 0.54 0.8 1.1 1.88 0.54 0.8 1.1 1.88 0.31 0.5 0.65 0.54 0.8 1.1 0.54 0.8 1.1 1.5 0.7 0.8 0.5 0.3 0.8 0.5 0.2 0.1 1.1 0.7 0.3 0.12 0.4 0.2 0.12 0.4 0.2 0.12 0.7 0.45 0.2 0.9 0.35 0.5 0.2 0.08 0.5 0.25 0.1 0.05 1.3 0.6 0.25 0.1 0.4 0.2 0.12 0.4 0.2 0.12 0.7 0.45 0.2 FWB IN OUT IN OUT Individual specifications FWB21 - 6 - Z -…
File type: application/pdf
Referenced at:
78 Discrete direct acting 2 port solenoid valve for water (special purpose valve) NC (normally closed) type, NO (normally open) type Port size: Rc1/8 to Rc1/2 FWB Series Common specifications Descriptions 1 2 3 4 5 4 5 7 10 4 5 7 10 3 4 5 4 5 7 4 5 7 0.036 0.15 0.31 0.5 0.65 0.54 0.8 1.1 1.88 0.54 0.8 1.1 1.88 0.31 0.5 0.65 0.54 0.8 1.1 0.54 0.8 1.1 1.5 0.7 0.8 0.5 0.3 0.8 0.5 0.2 0.1 1.1 0.7 0.3 0.12 0.4 0.2 0.12 0.4 0.2 0.12 0.7 0.45 0.2 0.9 0.35 0.5 0.2 0.08 0.5 0.25 0.1 0.05 1.3 0.6 0.25 0.1 0.4 0.2 0.12 0.4 0.2 0.12 0.7 0.45 0.2 FWB IN OUT IN OUT Individual specifications FWB21 - 6 - Z -…
File type: application/pdf
Referenced at:
78 Discrete direct acting 2 port solenoid valve for water (special purpose valve) NC (normally closed) type, NO (normally open) type Port size: Rc1/8 to Rc1/2 FWB Series Common specifications Descriptions 1 2 3 4 5 4 5 7 10 4 5 7 10 3 4 5 4 5 7 4 5 7 0.036 0.15 0.31 0.5 0.65 0.54 0.8 1.1 1.88 0.54 0.8 1.1 1.88 0.31 0.5 0.65 0.54 0.8 1.1 0.54 0.8 1.1 1.5 0.7 0.8 0.5 0.3 0.8 0.5 0.2 0.1 1.1 0.7 0.3 0.12 0.4 0.2 0.12 0.4 0.2 0.12 0.7 0.45 0.2 0.9 0.35 0.5 0.2 0.08 0.5 0.25 0.1 0.05 1.3 0.6 0.25 0.1 0.4 0.2 0.12 0.4 0.2 0.12 0.7 0.45 0.2 FWB IN OUT IN OUT Individual specifications FWB21 - 6 - Z -…
File type: application/pdf
Referenced at:
FLB Series 104 Common specifications Descriptions Standard specifications Optional specifications Voltage Model no. FLB2 FLB3/4/5 3mA or less 6mA or less 1.5mA or less 3mA or less 1mA or less 2mA or less 100 VAC 200 VAC 24 VDC 12 VDC Le ak ag e cu rre nt Working fluid Working pressure differential range Withstanding pressure (water pressure) Fluid temperature Ambient temperature Heat proof class Atmosphere Valve structure Valve seat leakage Installation attitude Protective structure AC: -10 to 60 DC: -10 to 40 (no freezing) -10 to 90 (no freezing) AC: -20 to 60 DC: -20 to 40 -20 to 60 B H or…
File type: application/pdf
Referenced at:
FLB Series 104 Common specifications Descriptions Standard specifications Optional specifications Voltage Model no. FLB2 FLB3/4/5 3mA or less 6mA or less 1.5mA or less 3mA or less 1mA or less 2mA or less 100 VAC 200 VAC 24 VDC 12 VDC Le ak ag e cu rre nt Working fluid Working pressure differential range Withstanding pressure (water pressure) Fluid temperature Ambient temperature Heat proof class Atmosphere Valve structure Valve seat leakage Installation attitude Protective structure AC: -10 to 60 DC: -10 to 40 (no freezing) -10 to 90 (no freezing) AC: -20 to 60 DC: -20 to 40 -20 to 60 B H or…
File type: application/pdf
Referenced at:
FLB Series 104 Common specifications Descriptions Standard specifications Optional specifications Voltage Model no. FLB2 FLB3/4/5 3mA or less 6mA or less 1.5mA or less 3mA or less 1mA or less 2mA or less 100 VAC 200 VAC 24 VDC 12 VDC Le ak ag e cu rre nt Working fluid Working pressure differential range Withstanding pressure (water pressure) Fluid temperature Ambient temperature Heat proof class Atmosphere Valve structure Valve seat leakage Installation attitude Protective structure AC: -10 to 60 DC: -10 to 40 (no freezing) -10 to 90 (no freezing) AC: -20 to 60 DC: -20 to 40 -20 to 60 B H or…
File type: application/pdf
Referenced at:
GUIDED CYLINDER STG SERIES GUIDED CYLINDER STG SERIES CC-781A 2 New Products High Precision/ High rigidity Ecological Additional variation New eco-friendly guided cylinder Guided cylinder STG Series (ø12 to ø80) - Remove toxic substances and protect the environment by preventing contamination Ecological product Harmful substances such as lead and hexavalent chrome that adversely affect the global environment are not used in the cylinder and cylinder switch. This product complies with the RoHS Directives in effect in the EU. (Lead-free solder and lead wires) Compatible with various applications…
File type: application/pdf
Referenced at: